Hotel & Minpaku Opening Check

Stage-1 report (sample)

A fictional property based on a case from our internal manual. It does not refer to any real building or address. Real reports follow the same structure. This page is a reference translation; Japanese reports are the authoritative version.

Parts of each item are hidden in this sample. The actual report gives everything in full.

1. Result

Result: Open issues to verify

The site has 5.5 m of frontage on a narrow road, but with a hotel area of 850 m² Tokyo's ordinance normally (hidden in this sample)

In stage 2 we will put these three questions to the architect and the building department.

  1. Does the frontage reach 6 (hidden in this sample)
  2. If not, does the (hidden in this sample)
  3. Does the floor plan (hidden in this sample)
Ready for architect reviewReady to move to an architect's review
Open issues to verifyOpen issues remain to be verified
Confirmed blockerA blocker is confirmed with evidence

2. Property facts

A whole office building is to be converted into a hotel.

ItemFactSource and date
Location and authoritiesA ward in Tokyo (fictional). (hidden in this sample)—
Current use, planned use, operationOffice → hotel (ryokan/hotel (hidden in this sample)Clien(hidden in this sample)
Zoning and district rulesCommercial zone, fire-prevention (hidden in this sample)Ward zoning (hidden in this sample)
Site area, gross floor area, area changing use380 m², 850 (hidden in this sample)Building (hidden in this sample)
Planned rooms24 rooms (6 per floor on (hidden in this sample)Client's (hidden in this sample)
Storeys and height5 above ground, no (hidden in this sample)Confirm(hidden in this sample)
Structure and fire resistanceReinforced concrete, built 1991 (hidden in this sample)Confirm(hidden in this sample)
Confirmation and completion certificatesBoth exist (1991). Seller (hidden in this sample)Copies from (hidden in this sample)
Stairs, lift, parkingOne interior (hidden in this sample)Confirmation(hidden in this sample)
Road type, width, frontageArticle 42-2 road, (hidden in this sample)Ward (hidden in this sample)
Floor-area ratio224% used. Cap (hidden in this sample)Area table (hidden in this sample)
OccupancyFully (hidden in this sample)Listi(hidden in this sample)

3. Five-minute check (seven gates)

Three of the seven gates are open and none is a blocker. The open items concentrate on roads, frontage and stairs.

GateResultFact → meaning → next check
1 ScopeReady for architect reviewTokyo, 5 storeys, 850 m² whole building changing use to (hidden in this sample)
2 ZoningReady for architect reviewCommercial zone, where hotels and (hidden in this sample)
3 Educational districts and local rulesReady for architect reviewThe zoning map shows no educational district, special-use (hidden in this sample)
4 Roads and flag lotsOpen issues to verifyDesignated-road map shows an Article 42-2 road, current width 3.8 m. Because it is under 4 (hidden in this sample)
5 Tokyo's required frontageOpen issues to verifyFor a hotel area of 850 m², Article 10-3 of the ordinance requires 6 m in principle. The whole (hidden in this sample)
6 Documents, fire resistance, floor-area ratioReady for architect reviewConfirmation and completion certificates exist. Drawings state fire-resistant building. As the (hidden in this sample)
7 Egress, fire service, inn licenceOpen issues to verifyOne interior staircase. Whether a second is required depends on the guest-room and total room area per (hidden in this sample)

4. What stage 2 must confirm

For the three open gates, stage 2 confirms the following. The answers largely decide whether the result rises to architect-ready or settles as a blocker.

GateWhat to confirmWith whom
4 Roads and flag lotsThe centre line and deemed (hidden in this sample)Architect (hidden in this sample)
5 Tokyo's required frontageWhether frontage reaches 6 m after the (hidden in this sample)Architect(hidden in this sample)
7 Egress, fire service, inn licenceWhether the floor plan needs a second (hidden in this sample)Arc(hidden in this sample)

Stage 2 also checks the whole building against 37 items.

5. Indicative cost and timing

No renovation cost can be given a range yet. The architect will estimate in stage 2.

  • Fire equipment (alarms, exit lighting), (hidden in this sample)
  • Construction cost if a second (hidden in this sample)
  • Business viability: depending on the frontage and (hidden in this sample)

Stage 2 (37-item check, architect's survey, pre-consultations, site visit) costs JPY 129,800 (excl. tax, in advance). Delivery depends on when the authorities can take the pre-consultation; we aim for the earliest date, typically one week to one month.

6. Disclaimer

  • “Ready for architect review” means the case is worth taking to an architect. It does not guarantee compliance or a licence
  • A blocker is given only when confirmed by official documents, an official's answer or an expert opinion
  • The report is based on the documents and public records available at the time. Later changes to law, ordinances or practice are not reflected
  • Whether a licence is granted is decided by the authorities when the application is reviewed
  • Costs and timing are indicative, not quotations